Suggestion box

From LabNation Wiki
Revision as of 19:01, 31 July 2018 by Riemerg (talk | contribs)
Jump to navigation Jump to search

Suggestions

Suggestion (software) Origin
Add pass-fail mask [1]
Separate size control for numbers on the grid [2]
Save to JSON format [3]
Select which channels to save to file [4]
Beep on trigger [5]
Measurements also applicable to Math/Operator waves [6]
FFT only on viewport (subsection of panorama) [7]
High-resolution multimeter mode (by changing offset voltage) [8]
Data logger functionality [9]
Possibility to switch off peak detect Vainney
Average instead of peak detect Vainney
Numpad: highlight value instead of removing it Ger
Documentation on USB protocol sigrok
After fetching RAM data: also update Panorama sigrok
Remove sliders and replace by numpads Karsten
Show preview of AWG function to upload Karsten
Save - replay functionality Robert
Frequency response tool [10]
Android keyboard support [11]
In-app decoder output listing [12]
On adding decoder: suggest to switch to require trigger or single trigger mode [13]
Cursors in FFT window. [14][15]
Record digital waveforms and reproduce them using digi-out [16]
Mac users - keyboard and mouse [17]
possibility to give a name to the channels like "CLK, status, CE_N, ..." [18]
digi trigger through context menu [19]
Re-arrange AWG menu [20]
Display measurements for digiwaves [21]
AWG defaulted to a DC offset of 0V, 3V P-P, and 1kHz so it can be used for probe comp [22]
Ensure lowest CPU consumption when acquisition is stopped [23]
Changing Colors for each channel would be a nice feature as well. [24][25][26]
what if we could customise the colours of grid, channels and background? [27]
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale [28]
highlight the actual points taken (digitized) on the display waveform [29]
scroll on the mouse to cycle through the logic analyser trigger condition [30]
Hover+scroll wheel changes trigger options [31]
Android touch button equiv of page up/dn and home end: [32]
AWG takes HEX values rather than voltages [33]
Digital output linked to AWG waveform [34]
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution [35]
convert Operator wave into reference wave [36]
Show AC/DC and trigger edge in bubble (same as x10) [37]
ability to turn off mousewheel [38]
ping-pong memory architecture [39]
duplex 4wire SPI output [40]
mode: fix trigger position [41]
measurement: low and high period time [Mail Tom]
trigger counter [42]
Suggestion (hardware) Origin
How about a nice fabric bag with a zipper, or better yet a clear one [43]

Suggestions which helped improving our app!

Suggestion Origin
Save decoder configuration [44]
Save and recall entire configuration [45]
save LA settings (trigger condition, arrangement of the channe) [46]
Support for current probes [47]
Support for 20x attenuators Vainney
Edge counter between cursors Vainney
save settings every minute or so [48]
X-Y mode [49]
Reference waveform [50]
I2C decoder: show W/R in address block Yentel
Need better FFT pan/zoom support [51]
Get that External trigger pin going [52]
xth pulse triggering, pulse width triggering [53]
independent analog channel triggering [54]
time based triggering to analog channels [55]
More complex trigger (hf reject etc) [56]
save contents of RAM to disk [57]
itd be nice if there was a record setting for just one screens worth. [58]
select max outliers to display on grid while subsampling on fpga [59]
"persistence" mode that would superimpose a number of traces on top of each other [60]
extend decoders so they can generate a new waveform [61]
Improve cursor contrast [62]
Utra hi speed mode, trace acumulation, persistance [63]
Option to invert analogwaves/digiwaves [64] [65]
Make analog indicators docable the same way as the digital indicators are [66]
Make height of indivisual graphs adjustable by dragging center bar [67]
Option to 'unpower' AWG in analog mode [68]
Sliders: numeric pad for exact value input [69]
Show deltas of last 2 vertical and last 2 horizontal cursors [70]
flash single/require trigger while not receiving data
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. [71]
allow 10ns/div [72]
key auto-repeat [73]
Right click or long press sets trigger to left 10% position [74]
UART decoder [75]
semi-automatic time measurement feature [76]
Would be nice to turn off channels not being used in the LA. [77]
Sample on how to control digital outputs from Matlab Jacobus
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself [78]

Suggestions we believed didn't really fit in our idea of a perfect SmartScope

Suggestion Origin
Scaling: window popup with the "canonical" time base or volt per division value [79]
scroll causes voltage zoom, shift-scroll for time-zoom (opposite of today) [80]