Suggestion box: Difference between revisions
Jump to navigation
Jump to search
m (→Suggestions) |
mNo edit summary |
||
Line 3: | Line 3: | ||
! Suggestion (software) | ! Suggestion (software) | ||
! Origin | ! Origin | ||
|- | |- | ||
| Data logger functionality || [https://www.lab-nation.com/forum/smartscope-api/topics/voltage-data-logger?page=1] | | Data logger functionality || [https://www.lab-nation.com/forum/smartscope-api/topics/voltage-data-logger?page=1] | ||
Line 21: | Line 19: | ||
|- | |- | ||
| On adding decoder: suggest to switch to require trigger or single trigger mode || [https://www.lab-nation.com/forum/software/topics/i-c-decoder-doesn-t-decode-when-it-samples-below-50mhz/posts/new?reply_to_id=1986] | | On adding decoder: suggest to switch to require trigger or single trigger mode || [https://www.lab-nation.com/forum/software/topics/i-c-decoder-doesn-t-decode-when-it-samples-below-50mhz/posts/new?reply_to_id=1986] | ||
|- | |- | ||
| Cursors in FFT window. || [https://www.lab-nation.com/forum/software/topics/version-2015-1001-0-50-linux-issue-wishes?page=1] | | Cursors in FFT window. || [https://www.lab-nation.com/forum/software/topics/version-2015-1001-0-50-linux-issue-wishes?page=1] | ||
Line 53: | Line 49: | ||
|- | |- | ||
| ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale || [https://www.lab-nation.com/forum/hardware/topics/questions-and-suggestions/posts/new?reply_to_id=791] | | ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale || [https://www.lab-nation.com/forum/hardware/topics/questions-and-suggestions/posts/new?reply_to_id=791] | ||
|- | |- | ||
| highlight the actual points taken (digitized) on the display waveform || [https://www.lab-nation.com/forum/hardware/topics/point-enhancement-mode] | | highlight the actual points taken (digitized) on the display waveform || [https://www.lab-nation.com/forum/hardware/topics/point-enhancement-mode] | ||
Line 63: | Line 55: | ||
|- | |- | ||
| Hover+scroll wheel changes trigger options|| [https://www.lab-nation.com/forum/software/topics/a-long-list-of-software-suggestions] | | Hover+scroll wheel changes trigger options|| [https://www.lab-nation.com/forum/software/topics/a-long-list-of-software-suggestions] | ||
|- | |- | ||
| Android touch button equiv of page up/dn and home end:|| [https://www.lab-nation.com/forum/software/topics/a-long-list-of-software-suggestions] | | Android touch button equiv of page up/dn and home end:|| [https://www.lab-nation.com/forum/software/topics/a-long-list-of-software-suggestions] | ||
Line 90: | Line 80: | ||
! Suggestion | ! Suggestion | ||
! Origin | ! Origin | ||
|- | |||
| Get that External trigger pin going || [https://www.lab-nation.com/forum/hardware/topics/external-trigger] | |||
|- | |||
| xth pulse triggering, pulse width triggering || [https://www.lab-nation.com/forum/software/topics/trigger-every-2nd-or-3rd-pulse?page=1] | |||
|- | |||
| independent analog channel triggering || [https://www.lab-nation.com/forum/hardware/topics/questions-and-suggestions/posts/new?reply_to_id=821] | |||
|- | |||
| time based triggering to analog channels || [https://www.lab-nation.com/forum/hardware/topics/questions-and-suggestions?page=1] | |||
|- | |||
| More complex trigger (hf reject etc)|| [https://www.lab-nation.com/forum/software/topics/a-long-list-of-software-suggestions] | |||
|- | |- | ||
| save contents of RAM to disk || [https://www.lab-nation.com/forum/hardware/topics/how-to-acquire-long-data-set?page=1] | | save contents of RAM to disk || [https://www.lab-nation.com/forum/hardware/topics/how-to-acquire-long-data-set?page=1] |
Revision as of 16:50, 3 February 2016
Suggestions
Suggestion (software) | Origin |
---|---|
Data logger functionality | [1] |
Edge counter between cursors | Vainney |
Documentation on USB protocol | sigrok |
Save decoder configuration | Alfons |
Remove sliders and replace by numpads | Karsten |
Show preview of AWG function to upload | Karsten |
In-app decoder output listing | [2] |
On adding decoder: suggest to switch to require trigger or single trigger mode | [3] |
Cursors in FFT window. | [4] |
Record digital waveforms and reproduce them using digi-out | [5] |
Mac users - keyboard and mouse | [6] |
possibility to give a name to the channels like "CLK, status, CE_N, ..." | [7] |
digi trigger through context menu | [8] |
save LA settings (trigger condition, arrangement of the channe) | [9] |
Re-arrange AWG menu | [10] |
save settings every minute or so | [11] |
Display measurements for digiwaves | [12] |
AWG defaulted to a DC offset of 0V, 3V P-P, and 1kHz so it can be used for probe comp | [13] |
Ensure lowest CPU consumption when acquisition is stopped | [14] |
X-Y mode | [15] |
Changing Colors for each channel would be a nice feature as well. | [16][17] |
what if we could customise the colours of grid, channels and background? | [18] |
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale | [19] |
highlight the actual points taken (digitized) on the display waveform | [20] |
scroll on the mouse to cycle through the logic analyser trigger condition | [21] |
Hover+scroll wheel changes trigger options | [22] |
Android touch button equiv of page up/dn and home end: | [23] |
AWG takes HEX values rather than voltages | [24] |
Digital output linked to AWG waveform | [25] |
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution | [26] |
Show AC/DC and trigger edge in bubble (same as x10) | [27] |
ability to turn off mousewheel | [28] |
Suggestion (hardware) | Origin |
---|---|
How about a nice fabric bag with a zipper, or better yet a clear one | [29] |
Suggestions which helped improving our app!
Suggestion | Origin |
---|---|
Get that External trigger pin going | [30] |
xth pulse triggering, pulse width triggering | [31] |
independent analog channel triggering | [32] |
time based triggering to analog channels | [33] |
More complex trigger (hf reject etc) | [34] |
save contents of RAM to disk | [35] |
itd be nice if there was a record setting for just one screens worth. | [36] |
select max outliers to display on grid while subsampling on fpga | [37] |
"persistence" mode that would superimpose a number of traces on top of each other | [38] |
extend decoders so they can generate a new waveform | [39] |
Utra hi speed mode, trace acumulation, persistance | [40] |
Option to invert analogwaves/digiwaves | [41] [42] |
Make analog indicators docable the same way as the digital indicators are | [43] |
Make height of indivisual graphs adjustable by dragging center bar | [44] |
Option to 'unpower' AWG in analog mode | [45] |
Sliders: numeric pad for exact value input | [46] |
Show deltas of last 2 vertical and last 2 horizontal cursors | [47] |
flash single/require trigger while not receiving data | |
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. | [48] |
allow 10ns/div | [49] |
key auto-repeat | [50] |
Right click or long press sets trigger to left 10% position | [51] |
UART decoder | [52] |
semi-automatic time measurement feature | [53] |
Would be nice to turn off channels not being used in the LA. | [54] |
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself | [55] |
Suggestions we believed didn't really fit in our idea of a perfect SmartScope
Suggestion | Origin |
---|---|
Scaling: window popup with the "canonical" time base or volt per division value | [56] |
scroll causes voltage zoom, shift-scroll for time-zoom (opposite of today) | [57] |