| Separate size control for numbers on the grid || [https://www.lab-nation.com/forum/software/topics/readibilty-of-minus-signs-on-y-axis?page=1]
| Separate size control for numbers on the grid || [https://www.lab-nation.com/forum/software/topics/readibilty-of-minus-signs-on-y-axis?page=1]
|-
| Don't switch to dummy scope when USB disconnected || [https://www.lab-nation.com/forum/software/topics/don-t-switch-to-dummy-scope-when-usb-disconnected]
|-
|-
| Save to JSON format || [https://www.lab-nation.com/forum/software/topics/recording-i2c-or-any-other-decoded-logic-signals]
| Save to JSON format || [https://www.lab-nation.com/forum/software/topics/recording-i2c-or-any-other-decoded-logic-signals]

Revision as of 20:57, 10 February 2019

Suggestions

Suggestion (software) Origin
Add pass-fail mask [1]
Separate size control for numbers on the grid [2]
Don't switch to dummy scope when USB disconnected [3]
Save to JSON format [4]
Select which channels to save to file [5]
Beep on trigger [6]
Measurements also applicable to Math/Operator waves [7]
FFT only on viewport (subsection of panorama) [8]
High-resolution multimeter mode (by changing offset voltage) [9]
Data logger functionality [10]
Possibility to switch off peak detect Vainney
Average instead of peak detect Vainney
Numpad: highlight value instead of removing it Ger
Documentation on USB protocol sigrok
After fetching RAM data: also update Panorama sigrok
Remove sliders and replace by numpads Karsten
Show preview of AWG function to upload Karsten
Save - replay functionality Robert
Frequency response tool [11]
Android keyboard support [12]
In-app decoder output listing [13]
On adding decoder: suggest to switch to require trigger or single trigger mode [14]
Cursors in FFT window. [15][16]
Record digital waveforms and reproduce them using digi-out [17]
Mac users - keyboard and mouse [18]
possibility to give a name to the channels like "CLK, status, CE_N, ..." [19]
digi trigger through context menu [20]
Re-arrange AWG menu [21]
Display measurements for digiwaves [22]
AWG defaulted to a DC offset of 0V, 3V P-P, and 1kHz so it can be used for probe comp [23]
Ensure lowest CPU consumption when acquisition is stopped [24]
Changing Colors for each channel would be a nice feature as well. [25][26][27]
what if we could customise the colours of grid, channels and background? [28]
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale [29]
highlight the actual points taken (digitized) on the display waveform [30]
scroll on the mouse to cycle through the logic analyser trigger condition [31]
Hover+scroll wheel changes trigger options [32]
Android touch button equiv of page up/dn and home end: [33]
AWG takes HEX values rather than voltages [34]
Digital output linked to AWG waveform [35]
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution [36]
convert Operator wave into reference wave [37]
Show AC/DC and trigger edge in bubble (same as x10) [38]
ability to turn off mousewheel [39]
ping-pong memory architecture [40]
duplex 4wire SPI output [41]
mode: fix trigger position [42]
measurement: low and high period time [Mail Tom]
trigger counter [43]
Suggestion (hardware) Origin
How about a nice fabric bag with a zipper, or better yet a clear one [44]

Suggestions which helped improving our app!

Suggestion Origin
Save decoder configuration [45]
Save and recall entire configuration [46]
save LA settings (trigger condition, arrangement of the channe) [47]
Support for current probes [48]
Support for 20x attenuators Vainney
Edge counter between cursors Vainney
save settings every minute or so [49]
X-Y mode [50]
Reference waveform [51]
I2C decoder: show W/R in address block Yentel
Need better FFT pan/zoom support [52]
Get that External trigger pin going [53]
xth pulse triggering, pulse width triggering [54]
independent analog channel triggering [55]
time based triggering to analog channels [56]
More complex trigger (hf reject etc) [57]
save contents of RAM to disk [58]
itd be nice if there was a record setting for just one screens worth. [59]
select max outliers to display on grid while subsampling on fpga [60]
"persistence" mode that would superimpose a number of traces on top of each other [61]
extend decoders so they can generate a new waveform [62]
Improve cursor contrast [63]
Utra hi speed mode, trace acumulation, persistance [64]
Option to invert analogwaves/digiwaves [65] [66]
Make analog indicators docable the same way as the digital indicators are [67]
Make height of indivisual graphs adjustable by dragging center bar [68]
Option to 'unpower' AWG in analog mode [69]
Sliders: numeric pad for exact value input [70]
Show deltas of last 2 vertical and last 2 horizontal cursors [71]
flash single/require trigger while not receiving data
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. [72]
allow 10ns/div [73]
key auto-repeat [74]
Right click or long press sets trigger to left 10% position [75]
UART decoder [76]
semi-automatic time measurement feature [77]
Would be nice to turn off channels not being used in the LA. [78]
Sample on how to control digital outputs from Matlab Jacobus
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself [79]

Suggestions we believed didn't really fit in our idea of a perfect SmartScope

Suggestion Origin
Scaling: window popup with the "canonical" time base or volt per division value [80]