Suggestion box

From LabNation Wiki
Revision as of 12:58, 18 January 2017 by Riemerg (talk | contribs)
Jump to navigation Jump to search

Suggestions

Suggestion (software) Origin
Support for current probes [1]
High-resolution multimeter mode (by changing offset voltage) [2]
Data logger functionality [3]
Possibility to switch off peak detect Vainney
Average instead of peak detect Vainney
Support for 20x attenuators Vainney
Numpad: highlight value instead of removing it Ger
Documentation on USB protocol sigrok
After fetching RAM data: also update Panorama sigrok
Save decoder configuration Alfons
Remove sliders and replace by numpads Karsten
Show preview of AWG function to upload Karsten
Save - replay functionality Robert
Frequency response tool [4]
Android keyboard support [5]
In-app decoder output listing [6]
On adding decoder: suggest to switch to require trigger or single trigger mode [7]
Cursors in FFT window. [8][9]
Record digital waveforms and reproduce them using digi-out [10]
Mac users - keyboard and mouse [11]
possibility to give a name to the channels like "CLK, status, CE_N, ..." [12]
digi trigger through context menu [13]
save LA settings (trigger condition, arrangement of the channe) [14]
Re-arrange AWG menu [15]
save settings every minute or so [16]
Display measurements for digiwaves [17]
AWG defaulted to a DC offset of 0V, 3V P-P, and 1kHz so it can be used for probe comp [18]
Ensure lowest CPU consumption when acquisition is stopped [19]
Changing Colors for each channel would be a nice feature as well. [20][21]
what if we could customise the colours of grid, channels and background? [22]
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale [23]
highlight the actual points taken (digitized) on the display waveform [24]
scroll on the mouse to cycle through the logic analyser trigger condition [25]
Hover+scroll wheel changes trigger options [26]
Android touch button equiv of page up/dn and home end: [27]
AWG takes HEX values rather than voltages [28]
Digital output linked to AWG waveform [29]
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution [30]
convert Operator wave into reference wave [31]
Show AC/DC and trigger edge in bubble (same as x10) [32]
ability to turn off mousewheel [33]
ping-pong memory architecture [34]
duplex 4wire SPI output [35]
mode: fix trigger position [36]
trigger counter [37]
Suggestion (hardware) Origin
How about a nice fabric bag with a zipper, or better yet a clear one [38]

Suggestions which helped improving our app!

Suggestion Origin
Edge counter between cursors Vainney
X-Y mode [39]
Reference waveform [40]
I2C decoder: show W/R in address block Yentel
Need better FFT pan/zoom support [41]
Get that External trigger pin going [42]
xth pulse triggering, pulse width triggering [43]
independent analog channel triggering [44]
time based triggering to analog channels [45]
More complex trigger (hf reject etc) [46]
save contents of RAM to disk [47]
itd be nice if there was a record setting for just one screens worth. [48]
select max outliers to display on grid while subsampling on fpga [49]
"persistence" mode that would superimpose a number of traces on top of each other [50]
extend decoders so they can generate a new waveform [51]
Improve cursor contrast [52]
Utra hi speed mode, trace acumulation, persistance [53]
Option to invert analogwaves/digiwaves [54] [55]
Make analog indicators docable the same way as the digital indicators are [56]
Make height of indivisual graphs adjustable by dragging center bar [57]
Option to 'unpower' AWG in analog mode [58]
Sliders: numeric pad for exact value input [59]
Show deltas of last 2 vertical and last 2 horizontal cursors [60]
flash single/require trigger while not receiving data
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. [61]
allow 10ns/div [62]
key auto-repeat [63]
Right click or long press sets trigger to left 10% position [64]
UART decoder [65]
semi-automatic time measurement feature [66]
Would be nice to turn off channels not being used in the LA. [67]
Sample on how to control digital outputs from Matlab Jacobus
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself [68]

Suggestions we believed didn't really fit in our idea of a perfect SmartScope

Suggestion Origin
Scaling: window popup with the "canonical" time base or volt per division value [69]
scroll causes voltage zoom, shift-scroll for time-zoom (opposite of today) [70]