Suggestions

Suggestion (software) Origin
Get that External trigger pin going [1]
Cursors in FFT window. [2]
save settings every minute or so [3]
Display measurements for digiwaves [4]
Make analog indicators docable the same way as the digital indicators are [5]
Ensure lowest CPU consumption when acquisition is stopped [6]
Option to invert analogwaves/digiwaves [7] [8]
select max outliers to display on grid while subsampling on fpga [9]
X-Y mode [10]
Changing Colors for each channel would be a nice feature as well. [11][12]
itd be nice if there was a record setting for just one screens worth. [13]
what if we could customise the colours of grid, channels and background? [14]
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale [15]
independent analog channel triggering [16]
allow 10ns/div [17]
time based triggering to analog channels [18]
highlight the actual points taken (digitized) on the display waveform [19]
scroll on the mouse to cycle through the logic analyser trigger condition [20]
"persistence" mode that would superimpose a number of traces on top of each other [21]
Hover+scroll wheel changes trigger options [22]
Utra hi speed mode, trace acumulation, persistance [23]
More complex trigger (hf reject etc) [24]
Android touch button equiv of page up/dn and home end: [25]
AWG takes HEX values rather than voltages [26]
Digital output linked to AWG waveform [27]
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution [28]
Show AC/DC and trigger edge in bubble (same as x10) [29]
extend decoders so they can generate a new waveform [30]
ability to turn off mousewheel [31]
Suggestion (hardware) Origin
How about a nice fabric bag with a zipper, or better yet a clear one [32]

Suggestions which helped improving our app!

Suggestion Origin
Make height of indivisual graphs adjustable by dragging center bar [33]
Option to 'unpower' AWG in analog mode [34]
Sliders: numeric pad for exact value input [35]
Show deltas of last 2 vertical and last 2 horizontal cursors [36]
flash single/require trigger while not receiving data
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. [37]
key auto-repeat [38]
Right click or long press sets trigger to left 10% position [39]
UART decoder [40]
semi-automatic time measurement feature [41]
Would be nice to turn off channels not being used in the LA. [42]
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself [43]

Suggestions we believed didn't really fit in our idea of a perfect SmartScope

Suggestion Origin
Scaling: window popup with the "canonical" time base or volt per division value [44]
scroll causes voltage zoom, shift-scroll for time-zoom (opposite of today) [45]