Suggestion box

From LabNation Wiki
Revision as of 22:20, 16 December 2015 by Riemerg (talk | contribs)
Jump to navigation Jump to search

Suggestions

Suggestion (software) Origin
Get that External trigger pin going [1]
Data logger functionality [2]
Edge counter between cursors Vainney
Documentation on USB protocol sigrok
Save decoder configuration Alfons
In-app decoder output listing [3]
On adding decoder: suggest to switch to require trigger or single trigger mode [4]
xth pulse triggering, pulse width triggering [5]
Cursors in FFT window. [6]
Record digital waveforms and reproduce them using digi-out [7]
possibility to give a name to the channels like "CLK, status, CE_N, ..." [8]
digi trigger through context menu [9]
save LA settings (trigger condition, arrangement of the channe) [10]
Re-arrange AWG menu [11]
save settings every minute or so [12]
Display measurements for digiwaves [13]
AWG defaulted to a DC offset of 0V, 3V P-P, and 1kHz so it can be used for probe comp [14]
Ensure lowest CPU consumption when acquisition is stopped [15]
X-Y mode [16]
Changing Colors for each channel would be a nice feature as well. [17][18]
what if we could customise the colours of grid, channels and background? [19]
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale [20]
independent analog channel triggering [21]
time based triggering to analog channels [22]
highlight the actual points taken (digitized) on the display waveform [23]
scroll on the mouse to cycle through the logic analyser trigger condition [24]
Hover+scroll wheel changes trigger options [25]
More complex trigger (hf reject etc) [26]
Android touch button equiv of page up/dn and home end: [27]
AWG takes HEX values rather than voltages [28]
Digital output linked to AWG waveform [29]
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution [30]
Show AC/DC and trigger edge in bubble (same as x10) [31]
ability to turn off mousewheel [32]
Suggestion (hardware) Origin
How about a nice fabric bag with a zipper, or better yet a clear one [33]

Suggestions which helped improving our app!

Suggestion Origin
save contents of RAM to disk [34]
itd be nice if there was a record setting for just one screens worth. [35]
select max outliers to display on grid while subsampling on fpga [36]
"persistence" mode that would superimpose a number of traces on top of each other [37]
extend decoders so they can generate a new waveform [38]
Utra hi speed mode, trace acumulation, persistance [39]
Option to invert analogwaves/digiwaves [40] [41]
Make analog indicators docable the same way as the digital indicators are [42]
Make height of indivisual graphs adjustable by dragging center bar [43]
Option to 'unpower' AWG in analog mode [44]
Sliders: numeric pad for exact value input [45]
Show deltas of last 2 vertical and last 2 horizontal cursors [46]
flash single/require trigger while not receiving data
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. [47]
allow 10ns/div [48]
key auto-repeat [49]
Right click or long press sets trigger to left 10% position [50]
UART decoder [51]
semi-automatic time measurement feature [52]
Would be nice to turn off channels not being used in the LA. [53]
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself [54]

Suggestions we believed didn't really fit in our idea of a perfect SmartScope

Suggestion Origin
Scaling: window popup with the "canonical" time base or volt per division value [55]
scroll causes voltage zoom, shift-scroll for time-zoom (opposite of today) [56]