Suggestion box

From LabNation Wiki
Revision as of 16:50, 3 February 2016 by Riemerg (talk | contribs)
Jump to navigation Jump to search

Suggestions

Suggestion (software) Origin
Data logger functionality [1]
Edge counter between cursors Vainney
Documentation on USB protocol sigrok
Save decoder configuration Alfons
Remove sliders and replace by numpads Karsten
Show preview of AWG function to upload Karsten
In-app decoder output listing [2]
On adding decoder: suggest to switch to require trigger or single trigger mode [3]
Cursors in FFT window. [4]
Record digital waveforms and reproduce them using digi-out [5]
Mac users - keyboard and mouse [6]
possibility to give a name to the channels like "CLK, status, CE_N, ..." [7]
digi trigger through context menu [8]
save LA settings (trigger condition, arrangement of the channe) [9]
Re-arrange AWG menu [10]
save settings every minute or so [11]
Display measurements for digiwaves [12]
AWG defaulted to a DC offset of 0V, 3V P-P, and 1kHz so it can be used for probe comp [13]
Ensure lowest CPU consumption when acquisition is stopped [14]
X-Y mode [15]
Changing Colors for each channel would be a nice feature as well. [16][17]
what if we could customise the colours of grid, channels and background? [18]
ability to load the saved CSV and MAT files and view the waveform on the Smartscope GUI, so we can zoom in and out to the voltage and time scale [19]
highlight the actual points taken (digitized) on the display waveform [20]
scroll on the mouse to cycle through the logic analyser trigger condition [21]
Hover+scroll wheel changes trigger options [22]
Android touch button equiv of page up/dn and home end: [23]
AWG takes HEX values rather than voltages [24]
Digital output linked to AWG waveform [25]
a package for the Raspberry Pi 2 running the default raspberry pi 2 Linux distribution [26]
Show AC/DC and trigger edge in bubble (same as x10) [27]
ability to turn off mousewheel [28]
Suggestion (hardware) Origin
How about a nice fabric bag with a zipper, or better yet a clear one [29]

Suggestions which helped improving our app!

Suggestion Origin
Get that External trigger pin going [30]
xth pulse triggering, pulse width triggering [31]
independent analog channel triggering [32]
time based triggering to analog channels [33]
More complex trigger (hf reject etc) [34]
save contents of RAM to disk [35]
itd be nice if there was a record setting for just one screens worth. [36]
select max outliers to display on grid while subsampling on fpga [37]
"persistence" mode that would superimpose a number of traces on top of each other [38]
extend decoders so they can generate a new waveform [39]
Utra hi speed mode, trace acumulation, persistance [40]
Option to invert analogwaves/digiwaves [41] [42]
Make analog indicators docable the same way as the digital indicators are [43]
Make height of indivisual graphs adjustable by dragging center bar [44]
Option to 'unpower' AWG in analog mode [45]
Sliders: numeric pad for exact value input [46]
Show deltas of last 2 vertical and last 2 horizontal cursors [47]
flash single/require trigger while not receiving data
there would be value in having a "Power OK" light or indication, even if it's back through software, that acceptable power is present. [48]
allow 10ns/div [49]
key auto-repeat [50]
Right click or long press sets trigger to left 10% position [51]
UART decoder [52]
semi-automatic time measurement feature [53]
Would be nice to turn off channels not being used in the LA. [54]
Individual pins can't be hidden (as in o-scope) giving no screen space for the bus itself [55]

Suggestions we believed didn't really fit in our idea of a perfect SmartScope

Suggestion Origin
Scaling: window popup with the "canonical" time base or volt per division value [56]
scroll causes voltage zoom, shift-scroll for time-zoom (opposite of today) [57]