SmartScope - Debug checklist: Difference between revisions

From LabNation Wiki
Jump to navigation Jump to search
No edit summary
 
Line 2: Line 2:


=Checking for short-circuits=
=Checking for short-circuits=
The first thing to check is whether some power rails might be shorted. This might happen when a component was exposed to excessive currents. Check whether none of the nets in the table below are connected to each other. Make sure you the image below to find out where to probe the nets.
The first thing to check is whether some power rails might be shorted. This might happen when a component was exposed to excessive currents. Check whether none of the nets in the table below are connected to each other, by checking either the bottom-left or top-right part of the table below. Make sure you the image below to find out where to probe the nets.
{| class="wikitable"
{| class="wikitable"
!
!

Latest revision as of 10:49, 1 March 2017

In case something happened to your SmartScope, you can send in your SmartScope for repair, or (since you're into electronics anyway) you might try to give it a shot yourself. This document gives you a starting point in pinpointing what might be the problem.

Checking for short-circuits

The first thing to check is whether some power rails might be shorted. This might happen when a component was exposed to excessive currents. Check whether none of the nets in the table below are connected to each other, by checking either the bottom-left or top-right part of the table below. Make sure you the image below to find out where to probe the nets.

GND 5V D3.3V_IO D3.0V D1.8V D1.2V NEG_1.1V
GND
5V
D3.3V_IO
D3.0V
D1.8V
D1.2V
NEG_1.1V

DebugPoints.png

Verifying supply rail voltages

Next, power the SmartScope and measure all voltages to see whether they're close enough to their expected value. Note: in the app, switch to Digital mode to power the D3.3V_IO net

Measured voltage
GND
5V
D3.3V_IO
D3.0V
D1.8V
D1.2V
NEG_1.1V